1
00:00:00,000 --> 00:00:01,140
¿Cómo se rehabilita un

2
00:00:01,140 --> 00:00:02,560
rotor de polos salientes?

3
00:00:02,560 --> 00:00:03,680
En 9 pasos,

4
00:00:03,680 --> 00:00:04,420
siempre en el mismo

5
00:00:04,420 --> 00:00:05,140
orden.

6
00:00:05,140 --> 00:00:05,860
Y el más importante

7
00:00:05,860 --> 00:00:06,820
es una prueba que

8
00:00:06,820 --> 00:00:07,580
se hace polo por

9
00:00:07,580 --> 00:00:08,420
polo.

10
00:00:08,420 --> 00:00:09,700
1. Le hablas a TEMISA

11
00:00:09,700 --> 00:00:10,820
Power Gen y planeamos

12
00:00:10,820 --> 00:00:12,100
la reparación contigo.

13
00:00:12,100 --> 00:00:13,900
2. Se desmontan los polos.

14
00:00:13,900 --> 00:00:15,700
3. Se limpian e inspeccionan

15
00:00:15,700 --> 00:00:16,860
las bobinas de campo.

16
00:00:16,860 --> 00:00:18,760
4. Resistencia de aislamiento de

17
00:00:18,760 --> 00:00:19,560
cada polo.

18
00:00:19,560 --> 00:00:21,500
5. El más importante:

19
00:00:21,500 --> 00:00:22,460
la caída de voltaje

20
00:00:22,460 --> 00:00:23,680
polo por polo.

21
00:00:23,680 --> 00:00:24,540
Un polo con espiras

22
00:00:24,540 --> 00:00:25,420
en corto marca menos

23
00:00:25,420 --> 00:00:26,460
que los demás.

24
00:00:26,620 --> 00:00:28,240
6. Se reparan o se

25
00:00:28,240 --> 00:00:29,480
reaíslan las bobinas dañadas.

26
00:00:29,480 --> 00:00:31,660
7. Se revisan las conexiones

27
00:00:31,660 --> 00:00:32,600
entre polos.

28
00:00:32,600 --> 00:00:34,140
8. Se montan los polos

29
00:00:34,140 --> 00:00:34,760
y se fijan en

30
00:00:34,760 --> 00:00:35,520
su lugar.

31
00:00:35,520 --> 00:00:38,220
9. Pruebas finales y balanceo.

32
00:00:38,220 --> 00:00:38,820
No es el rotor

33
00:00:38,820 --> 00:00:40,740
completo, es cada polo.

34
00:00:40,740 --> 00:00:41,940
Comenta POLOS y te

35
00:00:41,940 --> 00:00:42,860
decimos qué revisar en

36
00:00:42,860 --> 00:00:43,420
tu generador.