Salient pole rotor rehabilitation in 9 steps. The most important is the pole-by-pole voltage drop test, which reveals shorted turns.

Published · 59.9 seconds · subtítulos en español

Email ventas@temisapowergen.mxWhatsApp

Short answer

How is a salient pole rotor rehabilitated?

A salient pole rotor is rehabilitated in nine steps, always in the same order: the work is planned with the customer, the poles are removed, the field coils are cleaned and inspected, and the insulation of each pole is measured. The most important step is the pole-by-pole voltage drop: a pole with shorted turns reads lower than the rest. Then coils are repaired, connections checked, poles reinstalled, and final tests and balancing are done.

Video transcript

Download captions (.srt)
  1. 00:00

    How is a salient

  2. 00:00

    pole rotor rehabilitated?

  3. 00:02

    In 9 steps,

  4. 00:03

    always in the same

  5. 00:04

    order.

  6. 00:05

    And the most important

  7. 00:05

    one is a test

  8. 00:06

    done pole by pole.

  9. 00:08

    1. You call TEMISA Power

  10. 00:10

    Gen and we plan

  11. 00:11

    the repair with you.

  12. 00:12

    2. The poles are removed.

  13. 00:14

    3. The field coils are

  14. 00:16

    cleaned and inspected.

  15. 00:17

    4. Insulation resistance of each

  16. 00:19

    pole.

  17. 00:20

    5. The most important:

  18. 00:22

    the voltage drop test,

  19. 00:23

    pole by pole.

  20. 00:24

    A pole with shorted

  21. 00:25

    turns reads lower than

  22. 00:26

    the others.

  23. 00:27

    6. Damaged coils are repaired

  24. 00:29

    or reinsulated.

  25. 00:31

    7. The connections between poles

  26. 00:33

    are checked.

  27. 00:34

    8. The poles are mounted

  28. 00:36

    and secured in place.

  29. 00:37

    9. Final tests and balancing.

  30. 00:40

    It's not the whole

  31. 00:41

    rotor, it's each pole.

  32. 00:43

    Comment POLES and we'll

  33. 00:45

    tell you what to

  34. 00:45

    check on your generator.

  35. 00:46

    TEMISA Power Gen: over 70 years in generators and electrical machines, ISO 9001:2015 and CFE LAPEM certificate. Contact: ventas@temisapowergen.mx.

Questions from plant owners

What is the most important test on a salient pole rotor?

The pole-by-pole voltage drop. Voltage is applied to the field winding and each pole is measured; one with shorted turns reads lower than the rest.

Why is the insulation of each pole measured separately?

To locate which coil is damaged instead of only knowing that the whole rotor has a problem.

What is done with a damaged field coil?

It is repaired or reinsulated, the connections between poles are checked and, with the poles reinstalled, final tests and balancing are done.

Does TEMISA Power Gen rehabilitate salient pole rotors?

Yes, at the Tlajomulco, Jalisco shop. To quote, send the generator nameplate and rotor photos to ventas@temisapowergen.mx.

About the figures: Figures and graphics in the video illustrate the procedure. They are not a measurement from a serviced generator and they are not acceptance limits.

About the footage: Inserted photos are from the TEMISA Power Gen shop in Tlajomulco, Jalisco; the explanation is an animation and shows no customer data.

Narration of the TEMISA Power Gen explainer video.