Equipment · Turbogenerators
Turbogenerator Maintenance, Repair and Overhaul
Critical generation assets coupled to steam or gas turbines — from cogeneration plants to thermoelectric and combined cycle facilities of several hundred MW. Technical capacity under IEEE 115. Onsite and shop service in Mexico and Central America.
Specifications
Technical specifications
Verifiable capacities and typical ranges. For an asset-specific quote, write us with nameplate data, site conditions and operating regime.
Capacity
Up to
Speed
1,800 / 3,600 RPM
Voltage
Up to 15 kV
Coupling
Steam / gas turbines
Cooling
Air · H₂ · water
Insulation
Class F
Application
Thermal · combined cycle · cogeneration
CFE LAPEM
W4200-12
Services
Services available for turbogenerators
- Major maintenance with disassembly and core re-stacking
- Full stator and rotor rewind
- Commissioning under IEEE 115 with grid synchronization
- Electrical tests: RSO, ELCID, partial discharge, hipot AC/DC
- Stepped Hipot DC/AC with calibrated traceable equipment
- Rotor vibration analysis at 1,800/3,600 RPM under ISO 10816
- Boroscopic inspection of magnetic core and air gap
- CENACE coordination for outage windows when applicable
Contact
Need service for your industrial generator or turbogenerator?
Response within 24 hours. Formal quote within 48 hours. 24/7 emergency support across Mexico and Central America.
Direct line
+52 33 3614 2460Quote requests
ventas@temisapowergen.mxService hours
24/7 emergency support
Get a quote in 4 steps
Tell us what you need
Our 4-step quote form captures the essentials: service type, equipment, capacity and contact. Response in less than 24 hours, formal quote within 48.
ISO 9001:2015 · IEEE / IEC