Stator winding
Insulation resistance and polarization index, winding resistance, capacitance / dissipation factor and partial discharge assessment, as applicable to the diagnostic objective.

Service · Electrical testing
Stator and rotor electrical diagnostics with a test programme defined by the machine, history and objective. Insulation, RSO, low-flux, partial discharge and applied-voltage testing are selected for the agreed scope and procedure. Planned field and workshop service.
Tests we run
Diagnostics that anticipate failure months in advance. Calibrated equipment, certified engineers, signed protocols under international standards.
Procedure defined by scope
Repetitive Surge Oscillograph
Diagnose inter-turn shorts in rotor field windings. Results are assessed with machine history and the agreed procedure.
Procedure defined by scope
Electromagnetic Core Imperfection Detection
Diagnose stator magnetic core. Detects laminar shorts before rewind — prioritizes repair vs core replacement.
IEEE 1434
Offline + online PD measurement
Predictive insulation diagnosis on high-voltage generators. Results support condition assessment; they do not predict a guaranteed failure date.
IEEE 95-2002
High Voltage Test — stepped curve
Dielectric validation of insulation post-rewind and pre-commissioning. Test levels and suitability require a machine-specific assessment.
Each test executes with calibrated equipment traceable to national standards under ISO 9001:2015. Signed protocol delivered for operational release or regulatory audit.
Request a diagnosticThe test programme is selected after reviewing nameplate information, history, symptoms and previous results. It is not an automatic package for every generator.
Insulation resistance and polarization index, winding resistance, capacitance / dissipation factor and partial discharge assessment, as applicable to the diagnostic objective.
Insulation and winding resistance, impedance and RSO when appropriate to the machine configuration and the question being investigated.
Offline and online tests require different arrangements. Applied-voltage testing is only included where justified by the assessment and an agreed procedure. The report documents test conditions, results, limitations and recommended next steps.
Contact us during outage planning, before finalizing the schedule. Lead time is confirmed after reviewing technical information, scope, access, specialists, equipment and logistics. There is no single lead time for every machine.
No. An enquiry starts the assessment. Mobilization is scheduled once scope, commercial conditions, availability and required site preparation are confirmed.
Yes, subject to feasibility and availability. We define the sequence and work interfaces; combining services does not mean they can all run simultaneously.
PLANNED INSPECTIONS

This is a planned specialist service. Contact TEMISA as early as possible so we can review the machine, define scope and coordinate equipment, personnel and logistics. An enquiry does not reserve a date.
Share manufacturer, model, rating, site, inspection objective and proposed outage dates before finalizing the plant schedule.
We review drawings, photographs, history and access. We identify missing information and the specialists and equipment required.
The proposal defines tests, deliverables, exclusions, responsibilities and schedule. Mobilization requires confirmed availability and commercial conditions.
The site provides agreed access and equipment release. The team verifies readiness, coordinates other work and records the actual test coverage.
Findings, limitations and recommendations are delivered on the agreed timetable. Further tests or repairs are scoped separately.
Machine geometry, completeness of technical information, specialist and equipment availability, site preparation, location and travel or customs requirements. The proposal separates preparation, testing, reassembly and reporting; test duration is not total outage duration.
COORDINATED OUTAGE SERVICES
Low-flux core testing, wedge tightness and visual records.
Review scope →Ultrasonic and eddy current assessment. A planned service in Mexico, subject to access, agreed scope and specialist availability.
Review scope →Natural-frequency and impact-response assessment of generator end windings. Arrange your technical review with TEMISA ahead of the outage.
Review scope →Contact
Response and quote timing confirmed after reviewing your request. Emergency support by arrangement across Mexico and Central America.
Quote requests
ventas@temisapowergen.mxDirect line
+52 33 3614 2460Shop hours
Monday to Friday 8:30–17:30 and Saturday 8:30–13:30 (closed Sunday)
Get a quote in 4 steps
Our 4-step quote form captures the essentials: service type, equipment, capacity and contact. Response and quote timing depend on the information received and agreed scope.
ISO 9001:2015 · IEEE / IEC