Skip to content
WEG generator rectifier assembly documented by TEMISA
Rectifier assembly in a WEG generator from the TEMISA service archive.

Components · Project assessment

Excitation and rectifiers

Assessment of the exciter, diodes and excitation system connections.

Prepare an assessment request →

Compatibility and availability must be confirmed. The image does not imply stock availability or a direct replacement.

Application

When this page applies

  • A generator that does not build up voltage or shows unstable excitation.
  • Damaged diodes, varistors or connections in the rotating bridge.
  • Assessment of a regulator or exciter upgrade.

Compatibility

What we need to review

  • 01Generator, exciter and regulator models.
  • 02Diagram, part number and diode specifications.
  • 03Alarms, available tests and system condition.

Scope to be defined

From component to installation

  • Excitation circuit diagnosis.
  • Identification of compatible replacement components.
  • Assembly and testing defined in the proposal.
Related service →

Quote request

What to send for a quote

  • Generator and exciter nameplates; voltage regulator (AVR) make and model.
  • Excitation diagram and part number of the diodes or rectifier bridge.
  • Alarms, field current and voltage readings, and tests already performed.
  • Photographs of the rectifier bridge, connections and regulator.
  • Location and whether the generator is out of service.

If some data is missing, send what you have: open items are confirmed with the scope and nameplate data. Configuration, compatibility, schedule and warranty conditions are stated in writing in each proposal.

Prepare an assessment request →

If your generator is TD Power Systems

TEMISA is a non-exclusive authorized service representative for TDPS generators in Mexico (agreement dated 12 January 2026, signed 19 February 2026). Genuine parts are identified from the machine number or nameplate data. For other brands, TEMISA identifies the component and assesses a compatible replacement per project.

Genuine TD Power Systems generator parts on the TDPS México site (Spanish) ↗

External link to tdpsmexico.mx, the TDPS México site run by TEMISA Power Gen; not the official TD Power Systems site.

Prepare your technical request

Complete these details and review the draft. Then open it in your email application and attach the nameplate.

Share the nameplate, available drawings or dimensions, and integration requirements.

This page prepares a draft only. It does not send your request or upload attachments.

← Back to catalogueRequest this solution →